When.com Web Search

  1. Ads

    related to: gauge calibration

Search results

  1. Results From The WOW.Com Content Network
  2. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    This is called a limited calibration. But if the final measurement requires 10% accuracy, then the 3% gauge never can be better than 3.3:1. Then perhaps adjusting the calibration tolerance for the gauge would be a better solution. If the calibration is performed at 100 units, the 1% standard would actually be anywhere between 99 and 101 units.

  3. Gauge fixing - Wikipedia

    en.wikipedia.org/wiki/Gauge_fixing

    A particular choice of the scalar and vector potentials is a gauge (more precisely, gauge potential) and a scalar function ψ used to change the gauge is called a gauge function. [citation needed] The existence of arbitrary numbers of gauge functions ψ(r, t) corresponds to the U(1) gauge freedom of this theory. Gauge fixing can be done in many ...

  4. Gauge block - Wikipedia

    en.wikipedia.org/wiki/Gauge_block

    Gauge blocks (also known as gage blocks, Johansson gauges, slip gauges, or Jo blocks) are a system for producing precision lengths. The individual gauge block is a metal or ceramic block that has been precision ground and lapped to a specific thickness. Gauge blocks come in sets of blocks with a range of standard lengths.

  5. Gauge (instrument) - Wikipedia

    en.wikipedia.org/wiki/Gauge_(instrument)

    a cylindrical ring of steel whose inside diameter is finished to gauge tolerance and is used for checking the external diameter of a cylindrical object. Strain gauge: a device used to measure the strain of an object. Thread pitch gauge, also called a threading gauge, pitch gauge, or screw gauge a device used to measure the pitch or lead of ...

  6. Measurement system analysis - Wikipedia

    en.wikipedia.org/wiki/Measurement_system_analysis

    Common tools and techniques of measurement system analysis include: calibration studies, fixed effect ANOVA, components of variance, attribute gage study, gage R&R, [1] ANOVA gage R&R, and destructive testing analysis. The tool selected is usually determined by characteristics of the measurement system itself.

  7. Pressure measurement - Wikipedia

    en.wikipedia.org/wiki/Pressure_measurement

    Liquid-column pressure gauges have a highly linear calibration. They have poor dynamic response because the fluid in the column may react slowly to a pressure change. When measuring vacuum, the working liquid may evaporate and contaminate the vacuum if its vapor pressure is too high. When measuring liquid pressure, a loop filled with gas or a ...

  8. Hegman gauge - Wikipedia

    en.wikipedia.org/wiki/Hegman_gauge

    A Hegman gauge, sometimes referred to as a grind gauge, grind gage, or grindometer, is an instrument which indicates the fineness of grind or the presence of coarse particles and agglomeration in a dispersion. [1]

  9. Deadweight tester - Wikipedia

    en.wikipedia.org/wiki/Deadweight_tester

    A dead weight tester (DWT) is a calibration standard method that uses a piston cylinder on which a load is placed to make an equilibrium with an applied pressure underneath the piston. Deadweight testers are secondary standards which means that the pressure measured by a deadweight tester is defined through other quantities: length, mass and time.