When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Zinsco - Wikipedia

    en.wikipedia.org/wiki/Zinsco

    In 1963, Zinsco introduced the R-38 twin breaker, which was the only twin circuit breaker that also made contact on both bus-bars for 240 volts in a single breaker space. This made the Zinsco brand hugely popular with contractors and millions of Zinsco service panels and load centers were installed through the 60s and 70s.

  3. Stab-Lok - Wikipedia

    en.wikipedia.org/wiki/Stab-Lok

    Angie's List and NBC Bay Area both highlighted an October 2002 ruling in a New Jersey Superior Court, which found that FPE (Federal Pacific Electric), the manufacturer of the Stab-Lok breakers and panels, "knowingly and purposefully [sic] distributed circuit breakers which were not tested to meet UL standards as indicated on their label".

  4. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    In a "ground fault" or "earth fault", current flows into the earth. The prospective short-circuit current of a predictable fault can be calculated for most situations. In power systems, protective devices can detect fault conditions and operate circuit breakers and other devices to limit the loss of service due to a failure.

  5. Intermittent fault - Wikipedia

    en.wikipedia.org/wiki/Intermittent_fault

    A simple example of an effectively random cause in a physical system is a borderline electrical connection in the wiring or a component of a circuit, where (cause 1, the cause that must be identified and rectified) two conductors may touch subject to (cause 2, which need not be identified) a minor change in temperature, vibration, orientation ...

  6. Selectivity (circuit breakers) - Wikipedia

    en.wikipedia.org/wiki/Selectivity_(circuit_breakers)

    The purpose of selectivity is to minimize the impact of a failure on the network. Faults in an installation are, for example, overload and short circuit. [1] [2] There are four ways in which selectivity is achieved: [3] Current selectivity: different breaking capacities; Time selectivity: time delay before tripping of a breaker

  7. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    A circuit breaker is an electrical safety device designed to protect an electrical circuit from damage caused by current in excess of that which the equipment can safely carry (overcurrent). Its basic function is to interrupt current flow to protect equipment and to prevent fire.

  8. Single-line diagram - Wikipedia

    en.wikipedia.org/wiki/Single-line_diagram

    A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.

  9. Distribution board - Wikipedia

    en.wikipedia.org/wiki/Distribution_board

    A distribution board (also known as panelboard, circuit breaker panel, breaker panel, electric panel, fuse box or DB box) is a component of an electricity supply system that divides an electrical power feed into subsidiary circuits while providing a protective fuse or circuit breaker for each circuit in a common enclosure.